⚡ Polar Power Microgrid Simulator
Alaska Energy System — PCM Thermal Battery Integration
SPEED
Day 0 — 00:00
Temperatures
OUT
IN
Sun Condition
Fuel Tank
Battery
Simulation
TIME
SIM DAY
DAY OF YEAR
MONTH
GEN MODE
GENERATOR
0.0 kW
TODAY
SOLAR ELEC
🔆
SOLAR THERMAL
💨
WIND
🪵
WOOD STOVE
🔥 PCM Thermal Battery — Live Fill
Tank 1 — 100°F
Tank 2 — 180°F
Tank 3 — 250°F
🏠 Heat Delivery — Live Balance
Heat Demand
BTU/hr
Total Heat In
BTU/hr
Toyo Status
Balance
BTU/hr
⚡ DC Bus — Power Balance
Home Load
Batt Net
Waste Heat
CHP Eff
📅 Today's Totals
Gen run
Diesel burned
kWh gen
Waste heat recov
Solar kWh
Wind kWh
Heater fuel
ST heat / elec
⚡ Power Sources — 24 Hour Rolling
█ Gen █ Solar Elec █ Solar Thermal (kW-eq) █ Wind — Load
🌡 Temperature & Battery — 24 Hour Rolling
— Outdoor °F — Indoor °F — Battery %
⛽ Diesel Use — Daily History & Cumulative
0 days recorded  ·  0.0 gal total  ·  gal/day avg
█ Gen diesel (gal/day) █ Heater fuel (gal/day) — Cumulative (right axis) Today's partial day shown lighter
Building Configuration
Floor Area (sq ft)1100 sq ft
Ceiling Height (ft)8 ft
Wall R-ValueR-30
Roof R-ValueR-49
Floor R-ValueR-30
Window R-ValueR-3
Window Area (%)12%

Thermostat Setpoint68°F
Electrical Load1.0 kW avg
Alaska Region
Daily Temp Variation (±°F)±12°F
MonthJanuary
Building Heat Loss Analysis
UA Total
BTU/hr·°F
Heat Loss
BTU/hr now
Design Loss
BTU/hr @design
Thermal Mass
BTU/°F
Component Breakdown
Design Temperature
Polar Power 15kW — Run Control
Generator Mode
AUTO: Starts at 20% SoC, stops at 95% SoC
AI-AUTO: Solar-aware smart control — delays start if sun is coming, hard floor at 13%, always charges to 95% (long warm runs)
SCHEDULE: Runs on 24-hr schedule regardless of SoC
MANUAL ON/OFF: Override for testing or maintenance
Fuel Tank Capacity (gal)125 gal
Tank Starting Level100%
Generator Live Status
Status
STOPPED
DC Output
0 kW
Fuel Rate
0 gal/hr
Waste Heat
0 kBTU/hr
Active Mode
AI Gen State
Battery SoC
Start Threshold
Today
Run Hours
0.0
Diesel Used
0.0 gal
24-Hour Run Schedule
Click hours to toggle. Active in SCHEDULE mode only.
Scheduled hrs/day
0 hrs
Polar Power Specifications (Fixed)
Rated Output
15 kW
Operating Point
90% = 13.5 kW DC
Fuel Consumption
1.1 gal/hr diesel
Fuel Energy In
151,197 BTU/hr
Electrical Output
46,062 BTU/hr equiv
Waste Heat Total
105,135 BTU/hr
Recoverable Waste Heat
~70,000 BTU/hr
Voltage
48V DC
Cold Start Rating
-40°F
PCM Thermal Battery — 3 Tank Cascade
Cold return fluid enters Tank 1 → flows through Tank 2 → exits Tank 3 hot to heating load. Each tank uses a different PCM material at a different phase-change temperature.
Charge/Discharge Control Rules
PCM charges ONLY when generator is running
PCM discharges ONLY when generator is OFF
Discharge stops when Tank 3 fluid drops to ≤100°F
Toyo fires independently via thermostat — no PCM dependency
PCM Tank Gauges
Tank 1 — T1
62,500 BTU cap
Tank 2 — T2
68,750 BTU cap
Tank 3 — T3
75,000 BTU cap
PCM Materials Reference
Tank 1 PCM
Capric/Lauric acid eutectic — 100°F
Tank 2 PCM
Myristic acid eutectic — 180°F
Tank 3 PCM
NaNO₃/KNO₃ nitrate salt — 250°F
Total Capacity
206,250 BTU
Heat Source T3
Exhaust glycol loop ~300°F
Heat Source T2
Engine coolant loop ~190°F
Heat Source T1
Residual gen heat (always)
Battery Bank
Battery Capacity (kWh)50 kWh
Battery Status
SoC
Stored kWh
Charge Rate
Runtime Left
Thresholds
AUTO start SoC
20%
AI-AUTO hard floor
13% (starts always)
AI-AUTO solar delay zone
13–30% (waits for sun)
Charge target (both modes)
95% (full long run)
Round-trip Eff.
94%
DC Bus — Power Flow
Gen In
kW DC
☀ Solar + 💨 Wind
kW DC
Home Load
kW
Battery Net
kW
CHP Electrical Efficiency
Electrical Efficiency
13.5 kW ÷ 151,197 BTU/hr = 30.5%
CHP Combined Efficiency
kWh per Gallon Diesel
12.27 kWh/gal
Lifetime Totals
kWh Generated
Generator Hours
Diesel Consumed
Backup / Primary Heater
Heater Type
Toyo Model
Fuel Prices
Diesel / Heating Oil ($/gal)$4.50
Propane ($/gal)$5.25
Heater Status
Status
Output
Fuel Rate
Run Hrs Today
🔥 Wood Fire Status
STANDBY
Toggle this when you physically light or extinguish your wood stove. The system will immediately account for the fire's heat output, reduce Toyo demand, prioritize PCM Tank 3 charging, and update AI fuel forecasts.
Fire Session Statistics
⚡🔥 Renewable Routing Priority
Controls where solar thermal panel output goes — to PCM Tank 3 heating elements (heat) or to the DC bus as electricity. Electrical solar and wind always go to the DC bus/battery regardless.
SMART rules (applied to all renewables when solar thermal heating elements are connected):
Battery < 50% → ⚡ electric — all solar & wind charge the battery
Battery ≥ 50% AND Tank 3 < 90% → 🔥 heat — solar & wind feed Tank 3 elements
Otherwise → ⚡ electric
Heating System Flow
Heat Sources Active This Minute
Heat Demand
Q-Loss Now
BTU/hr
Total Heat In
BTU/hr
Net Balance
BTU/hr
Toyo Model Specifications
ModelOutputMax gal/hrBTU/hr
Toyo 5535,000 BTU/hr0.3035,000
Toyo 9050,000 BTU/hr0.4350,000
Toyo 15588,000 BTU/hr0.7588,000
All consume diesel/heating oil at 86–87% efficiency (137,452 BTU/gal HHV)
Wood Stove Configuration
🪵 Wood stove fires on schedule at set output — always supplemental
🔥 PCM discharges when generator is off (until T3 fluid hits 100°F)
🛢 Toyo covers any remaining gap to meet thermostat setpoint
⚡ Generator runs only to charge battery (SoC 20% → 95%)
24-Hour Burn Schedule
Wood heat is SUPPLEMENTAL — PCM and Toyo still operate independently.
Schedule Mode
AUTO — Temperature rules (no override)
AI — Lookahead engine sets schedule each cycle
MANUAL — You pick the hours; AI never touches it
AUTO schedule rules (by monthly avg temp):
> 40°F — Wood stove OFF (summer / shoulder season)
20–40°F — Morning burn 6am–noon (6 hrs/day)
< 20°F — Heavy burn 6am–10pm (16 hrs/day)
AUTO Schedule (this month) — read only
Active scheduled hrs/day
0 hrs/day
☀ Solar Array Configuration
🔆 Solar Electric Heating Elements — Tank 3 (PCM Thermal Battery)
💨 Wind Turbine Configuration
⚡ Live DC Bus Power Flow — Last 24 Hours
█ Generator █ Solar (Elec) █ Wind █ Solar Thermal (kW-equiv heat → Tank 1) — Home Load
🔋 Battery SoC with Renewable Fill Contribution
— Battery SoC % ▓ Solar fill ▓ Wind fill
💨 Wind Speed & Turbine Status
☀ Solar Irradiance Profile Today
Renewable Impact Summary
☀ Solar kWh Today
0.0
💨 Wind kWh Today
0.0
⚡ Renew Now
0.0
Gen Hrs Saved/Day
Diesel Saved/Day
Est Annual Savings
Combined System Cost (incl. Renewables)
⛽ Total Diesel (gen)
—/month projected
🛢 Heater Fuel
—/month projected
💰 Fuel Savings vs Toyo-Only
—/month
⏱ Engine Hours
—/month
🔥 Waste Heat Recovered
—/month
📅 Fuel Autonomy
days remaining
30-Day Fuel Consumption History
Performance Scorecard
Monthly & Annual Projections
Diesel Price ($/gal)$4.50
Heating Oil Price ($/gal)$4.50
Wood Price ($/cord)$250
PeriodGen DieselDiesel $Heater FuelHeater $Wood (lbs)Wood $Total Energy $Engine Hrs
☀ Seasonally-Adjusted Annual Projection — uses NOAA daylight data, regional temps, and building UA across all 12 months
Wood stove is assumed active Oct–Apr (when outdoor temp < 40°F per schedule). Solar/wind output varies by month using Alaska daylight hours and sun-angle data.
MonthAvg °FDaylightRenew→Heat kBTUGen DieselHeater FuelWood lbsGen $Heat $Wood $Total $
Wood Fuel Detail — current month / current schedule
Pieces/Day (est)
~8 lbs/piece avg
Lbs/Day
Wood $/Month
System Payback
Total System Cost
Simple Payback
vs full-year diesel-only baseline
🤖 AI Control System
When enabled, the AI runs a 24-hour lookahead simulation every few minutes and automatically adjusts: generator mode, wood stove schedule, and solar thermal routing to minimize fuel use while keeping the home comfortable.
Active Control Decisions
Enable AI Control to see decisions
📊 24-Hour Strategy Scores
Run lookahead to see strategy comparison
🪵 Fire Building Advisor
Run lookahead or ask AI for fire advice
📈 24-Hour Predictive Lookahead — Battery & PCM Forecast
— Battery SoC (optimal) — Battery SoC (no-AI) — PCM level (optimal) — PCM level (no-AI) █ Recommended fire window
💬 Ask the AI — Homeowner Assistant